Gurgling Noise

Home Forums Public Forums Drainage & Sewerage Gurgling Noise

Viewing 1 reply thread
  • Author
    Posts
    • #279362
      Avatar photoMasterPlumbers
      Keymaster

        Help! Cannot get rid of a gurgling noise that now occurs after the sump pump is finished cycling. This began after we installed a back-up system (Ace in the Hole). We added another check valve just above the backup, but that didn’t help. Any suggestions? Thanks!

      • #300641
        Avatar photoDUNBAR
        Participant

          Did you drill a hole in the pipe above the male adapter that screws into the main pump?

          It should be about a 1/8″ hole and within 6″ of the adapter.

          This prevents the pump from “locking and lets water drain back out of vertical pipe from check valve.

      Viewing 1 reply thread